Knowing which Sewage Pumping Station is right for you can be difficult, this is where PPS can help.

As a rule of thumb, Sewage Pumping Stations require 150 litres / per person / per day. This is known as 24-hour emergency storage. For example, for 4 occupants, you would require 600 Litres worth of storage.

For single properties, you can get away with installing a Single Pumping Station, however we would recommend you purchase a High Level Alarm. In the unfortunate event the pump breaks down / blocks, the water level will rise and signal an audible alarm, this will alert you that there is an issue. PPS do however recommend a Twin Sewage Pump Station as there is then a backup pump if ever required. 

Where there are multiple properties being pumped into one pumping station, a Twin Pumping Station is required. There is an alternative option to have one pumping station per property, so they are maintained individually. 

If you have any questions on which system is right for you, please do not hesitate to contact the team on 01332 854868.

 

By Josh Walker

Share:

Just added to your wishlist:
My Wishlist
You've just added this product to the cart:
Go to cart page

Welcome to Shopify Store

I act like:

Select Country: